Pressure compensator for open centre load sensing

Pressure compensator for open centre load sensing

The valve is required for load sensing applications with a fixed displacement pump (open centre).

  • Adjustment: hydraulic
  • Differential pressure 0.055 MPa (5.5 bar)
  • Operating pressure 6 MPa (60 bar)
  • Maximum permissible pressure 12 MPa (120 bar)
  • Low-leakage, self-sealing coupling nipples
  • Quick action mounting system Quick-Fix