Diaphragm accumulator with shut-off block

Diaphragm accumulator with shut-off block

With the three-way ball valve integrated in the shut-off block the following functions are possible:
1. Open connection between P and the diaphragm accumulator
2. Closed connection between P and the diaphragm accumulator
3. Open connection between T and the diaphragm accumulator (relief)

  • Safety valve against overload
  • Pressure gauge for working pressure
  • Rated volume 0.32 dm³
  • Medium, gas side: nitrogen (N)
  • Gas charging pressure when delivered p 1 MPa (10 bar)
  • Operating pressure 6 MPa (60 bar)
  • Maximum permissible pressure 12 MPa (120 bar)
  • Low-leakage, self-sealing coupling nipple for P
  • Tube with open quick coupling plug for T
  • Material for mounting on the profile plate

 

 

Customer Service Line: