Function
The mixing station mixes different recipes from three reservoir tanks. The liquid from one of the three reservoir tanks is pumped into the main tank in a controlled manner by opening the respective two-way ball valve. The finished mixture can be pumped to the next station via a second pump – or pumped back to the reservoir tank.
Measurement and control
Using a constant flow rate, the three raw materials are mixed to a recipe in the mixing station. The flow rate is recorded by means of an electronic flow sensor with impeller and additionally displayed using a variable-area flowmeter. The output signal from the flow sensor is converted to a standard signal from 0 – 10 V. The mixing station can also be actuated through binary means using the integrated comparator. The controller adjusts the necessary flow rate via the pump with analogue control – using a simple two-point controller or various dynamic controllers such as P, PI or PID. This permits a clear explanation of control technology on various levels.
Always the right mixture
The component mix of the mixing station offers a wide selection of typical components from process engineering. Pumps and process valves, various sensors for signal detection as well as electronic modules for signal conversion permit the right 'training mix'.
Sensors for detecting the filling level of containers. With overflow protection thanks to additional sensors on each container, thereby virtually eliminating the possibility of overflow.
Signal converters convert all analogue signals from the station to standard signals from 0 – 10 V. Practical for the purpose of experimentation: integrated comparators also supply purely binary signals.
Two-way ball valve with SYPAR scotch yoke rotary actuator, large optical display and directly connected NAMUR valve.
Training aims for project work
- Construction, wiring and commissioning of a system for process technology
- Selection, application and connection of various flow sensors
- Measurement of electrical and process-related variables such as level and flow rate
- Design and commissioning of control circuits
- Analysis of control processes and control circuits
- Parameterisation and optimisation of P, PI or PID controllers
- Drafting of open-loop and closed-loop control programs
- Process operation and monitoring
- Inspection, maintenance and servicing
Recommended training media
- Fluid Lab®-PA
- Web-based training program, Fundamentals of open and closed-loop control
- Design and simulation program FluidSIM® Pneumatics
Also order:
MPS® PA workbook
doporučené příslušenství
- PLC board with SIMATIC S7-300 – The industry standard (objednací číslo 533526)
- SIMATIC S7 connecting cable set (objednací číslo 544296)
- PLC board with CPX-FEC® (objednací číslo 541187)
- Festo CPX connecting cable set (objednací číslo 544297)
- PLC board with Allen Bradley MicroLogix 1500 (objednací číslo 544300)
- Allen Bradley MicroLogix connecting cable set (objednací číslo 544298)
- PLC board with Mitsubishi MELSEC (objednací číslo 544301)
- Mitsubishi MELSEC connecting cable set (objednací číslo 544299)
- SIMATIC S7 EduTrainer® Compact (objednací číslo 533018)
- SIMATIC S7 connecting cable set (objednací číslo 544296)
- Fluid Lab®-PA (objednací číslo 544304)
- EasyPort USB – An interface for measuring, open-loop control, closed-loop control. Connects the simulation to the real world (objednací číslo 548687)
- PC data cable RS232 (objednací číslo 162305)
- RS232 USB adapter (objednací číslo 540699)
- I/O data cable with SysLink connectors (IEEE 488) at both ends (objednací číslo 34031)
- Analogue cable, parallel (objednací číslo 529141)
- Simulation box, digital/analogue (objednací číslo 526863)
- I/O data cable with SysLink connectors (IEEE 488) at both ends (objednací číslo 34031)
- Analogue cable, parallel (objednací číslo 529141)
- PID industrial closed-loop controller (objednací číslo 544293)
- Mains cable