FP 1130
- Pressure range*: 0 – 1000 kPa (0 – +10 bar)
- Max. perm. pressure: 1400 kPa (14 bar)
- Supply voltage VB: 12 – 30 V DC
- Voltage output: 0 – 10 V
- Current output: 0 – 20 mA
- Total error: ±1 % of full-scale value
- Max. measuring frequency: 100 Hz
- Electrical protection: Short circuit proof, polarity reversal protection, overvoltage-proof up to 50 V DC (short-term)
*The sensor provides a signal even if pressure <0 bar. Linearity and proportionality are not guaranteed in this case.