TP 201, BIBB-EP, TP 601, TP 702
The electrical limit switch comprises a mechanically operated microswitch. When the roller lever is pressed, for example by the control cam of a cylinder, the microswitch is actuated. The circuit is closed or opened via the contacts. The microswitch can be wired as a normally-open, normally-closed or changeover contact.
- Contact load: Maximum 5 A
- Switching frequency: Maximum 200 Hz
- Reproducible accuracy: 0.2 mm
- Switch travel: 2.7 mm
- Actuator force: 5 N