Limit switch, electrical, left-actuated

Limit switch, electrical, left-actuated

TP 201, BIBB-EP, TP 601, TP 702

The electrical limit switch comprises a mechanically operated microswitch. When the roller lever is pressed, for example by the control cam of a cylinder, the microswitch is actuated. The circuit is closed or opened via the contacts. The microswitch can be wired as a normally-open, normally-closed or changeover contact.

  • Contact load: Maximum 5 A
  • Switching frequency: Maximum 200 Hz
  • Reproducible accuracy: 0.2 mm
  • Switch travel: 2.7 mm
  • Actuator force: 5 N

 

 